- 25001 OUT_OF_MEMORY Not enough memory to complete the request/action.
- 25002 UNSUPPORTED_VERSION An unsupported version of Visual Basic attempted to use DataTools Engine.
- 25003 UNKNOWN_CONNECTOR_TYPE Returned in two different contexts, as follows:
- 25004 UNKNOWN_ACTION Returned when an application tries to assign an invalid action.
- 25005 INVALID_FIELD_INDEX An invalid field index or an invalid field name was encountered.
- 25006 INVALID_OPTION An error was encountered trying to retrieve a connector option value from a connector.
- 25007 FIELD_NAME_NOT_DEFINED Returned when an application attempts to reference an invalid line style field name.
- 25008 INVALID_IMPORT_CONTROL The source on the transformation is invalid or unspecified. Certain API functions require that a source be bound to a target to execute properly. In addition, the Import Transformation and Export Transformation options require a valid source bound to a valid target.
- 25009 NO_CONNECTION No connection established for data source. Can occur on a source or a target.
- 25010 INVALID_EXPRESSION An expression is invalid. The expression may not be syntactically correct, or it may reference undefined fields.
- 25011 FIELD_NAME_TOO_LONG Specified field name exceeds the maximum length for field names for the currently selected connector. This error occurs when defining fields.
- 25012 FIELD_NAME_BAD_CHAR Assigned field name includes one or more invalid characters for the current connector type.
- 25013 FIELD_NAME_RESERVED_WORD Specified field name is invalid because it is a reserved word.
- 25014 FIELD_NAME_NOT_UNIQUE Field name that is not unique is encountered.
- 25015 UNKNOWN_BROWSER_TYPE Browser type is unknown or not supported.
- 25016 FIELD_COUNT_EXCEEDED Field count has been exceeded.
- 25017 INDEX_ERROR Returned when an application attempts to use an index for an array that is out of range.
- 25018 VALUE_ERROR A value is out of range or invalid.
- 25019 UNKNOWN_DATA_TYPE This error is returned when an invalid datatype name is assigned.
- 25020 LOSS_OF_PRECISION A field definition has been copied from the layout for one data source to the layout of another data source, and the target layout does not support a compatible datatype with the same precision as the data type for the source field definition. This is considered a warning for most applications.
- 25021 INVALID_STYLE_CONTROL The application has made a request that requires that the DJText control be bound to the DJStyle control.
- 25022 INVALID_STYLE_INDEX An invalid index was specified for a line style in the DJText control.
- 25023 STYLE_NAME_NOT_DEFINED An invalid line style name was specified as an index for a line style in the DJText control.
- 25024 STYLE_NAME_NOT_UNIQUE An attempt was made to add a new line style definition in the DJText control and a line style with the same name has already been defined.
- 25025 OPTION_SCHEMA_CONFLICT A connector option was set that may invalidate the target structured schema. This can happen in situations where the application is appending data to an existing file, and the file format is a format that determines record characteristics based on options settings, and there is a connection to the target data. For example, the application has designed a transformation specification that uses append mode with a fixed ASCII target file and then changes the record separator. The fixed ASCII connector uses the record separator to determine the record lengths. If the target layout is designed with the assumption of one record length and the option setting changes this assumption, the layout is likely to be invalid. The best way to avoid this sort of problem is to make sure all option settings are made prior to layout design.
- 25026 IMPORT_TRANSFORMATION Error importing the transformation.
- 25027 EXPORT_TRANSFORMATION Error exporting the transformation.
- 25028 EXPORT_PARTIAL Exporting partial transformations is invalid. A partial transformation is a transformation specification that is missing an active connection for either the source or target data. Exports of partial transformations are not currently supported. The application should ensure that both halves of the transformation are connected and try again.
- 25029 NO_REJECT_FILE During a transformation, if one of the mapping Expressions calls the Reject() Function and no reject log is connected, the error callback routine will be called passing this error code. This is considered a warning for the application user, so it is fired only once during a transformation. See also "Reject Function" in RIFL Programmer’s Reference Manual.
- 25030 TRANSFORMATION_ABORTED If a transformation is aborted with either the DJAbort API function or by a map expression calling the Abort() function, the error callback routine will be called with this error code. This is an advisory error code. See also "Abort Function" in RIFL Programmer’s Reference Manual).
- 25031 BUFFER_TOO_SMALL A buffer passed to receive a value that is too small for the entire value to be returned.
- 25032 UNCOMMITTED_TRANSACTION_BATCH An uncommitted transaction was encountered.
- 25033 TRANSACTION_BATCH_NOT_STARTED A commit transaction or rollback transaction was requested when a transaction had not previously been started.
- 25034 TRANSACTION_BATCH_TOO_LARGE The size limit on a batch transaction has been exceeded.
- 25035 SOURCE_TARGET_LICENSE Licensing error. Invalid combination of source and/or target types.
- 25036 RECORD_LAYOUT_NOT_DEFINED Record layout not specified.
- 25037 INVALID_RECORD_LAYOUT_INDEX Invalid structured schema index.
- 25038 RECORD_LAYOUT_NAME_NOT_UNIQUE Record layout name not unique.
- 25039 RECORD_RULE_NOT_DEFINED Record discriminator rule not defined.
- 25040 INVALID_RECORD_RULE_INDEX Invalid record rule index.
- 25041 RECORD_RULE_NAME_NOT_UNIQUE Record rule name encountered that is not unique.
- 25042 INVALID_RECORD_RULE_CONDITION Invalid record rule condition encountered.
- 25043 INVALID_EVENT_ACTION Invalid event action encountered.
- 25044 INVALID_FIELD_NAME Invalid field name encountered.
- 25045 INVALID_RECORD_LAYOUT_NAME Invalid structured schema name encountered.
- 25046 SAVE_TRANSFORMATION Indicates an error was encountered while saving the transformation. Specific error details are written to the log file.
- 25047 LOAD_TRANSFORMATION Indicates an error was encountered while loading the transformation. Specific error details are written to the log file.
- 25048 LOAD_MAP Indicates an error was encountered while loading the map. Specific error details are written to the log file.
- 25049 SAVE_MAP Indicates an error was encountered while saving the map. Specific error details are written to the log file.
- 25050 INVALID_CONVERSION_XML Indicates an invalid or corrupt transformation file was encountered (.tf.xml)
- 25051 INVALID_MAP_XML Invalid map XML. Indicates an invalid or corrupt map file was encountered (.map.xml)
- 25052 LOAD_STRUCTURED_SCHEMA Indicates an error was encountered while loading the structured schema.
- 25053 SAVE_STRUCTURED_SCHEMA Indicates an error was encountered while saving the structured schema.
- 25054 INVALID_STRUCTURED_SCHEMA_XML Invalid structured schema XML.
- 25055 INVALID_VALIDATION_TYPE Invalid validation type encountered.
- 25056 VALIDATION_ERROR Validation error encountered.
- 25057 INVALID_ACTION_EXPRESSION Invalid action expression encountered.
- 25058 INVALID_DATACHANGE_MONITOR_EXPRESSION Invalid Datachange Monitor Expression encountered.
- 25059 INVALID_ACTION_MAP Invalid action map encountered.
- 25060 INVALID_ACTION_KEYS Invalid action keys encountered.
- 25061 INVALID_FILTER_EXPRESSION Invalid filter expression encountered.
- 25062 INVALID_CONNECTION_INFO Invalid connection information encountered.
- 25063 INVALID_FIELD_EXPRESSION Invalid field expression encountered.
- 25064 INVALID_DISCRIMINATOR_RECORD_RULES Invalid discriminator record rules encountered.
- 25065 INVALID_CODE_MODULE Invalid code module encountered.
- 25066 XML_PARSE_ERROR Indicates an error was encountered while parsing an XML document.
- 25067 XML_READ_ERROR Indicates a read error was encountered while reading the XML document.
- 25068 XML_WRITE_ERROR Indicates an error was encountered while writing the XML document.
- 25069 XML_PARSER_INITIALIZATION_ERROR XML parser initialization error encountered.
- 25501 EOF End of file (EOF) error. An attempt was made to read a nonexistent record.
- 25502 BADNAME Specified file name is invalid, or the file does not exist.
- 25504 READERR An error was encountered reading file or table.
- 25505 NOMEM Out of memory.
- 25507 CREATERR Error encountered when creating file or table.
- 25508 WRITERR Error writing to a file or table.
- 25509 NOSPACE No space available on disk.
- 25510 INDEX_ERROR Index error encountered.
- 25511 RECTOOBIG Record definition is too large. The Structured Schema contains too many fields, or the combined size of each of the fields exceeds the maximum record length for the data format.
- 25512 NOSOURCE An attempt was made to perform some operation on a data source and the data source is not connected.
- 25513 BADLOGIC An internal error occurred while attempting to set a connector option.
- 25514 BADUPDATEOPTS An internal error occurred while initializing the Update option settings after a target connector is switched to Update mode.
- 25515 BADMATCH Target layout and target file or target definitions do not match.
- 25516 BADMODE The application attempted to set an invalid output mode for target data.
- 25517 INDEX_INVALID An attempt was made to define an invalid index. One or more of the fields in the index do not exist in the layout.
- 25518 NOLAYOUT No fields defined for the target data and an attempt was made to open the target for output.
- 25519 OPENERR Error opening data source.
- 25520 BADFILETYPE Invalid or corrupt data file.
- 25521 DELETERR Unable to delete a file, drop a table, or delete all of the records from the target data.
- 25522 INDEX_UNSUP Unsupported index.
- 25523 SQL_NOSERVER Bad or missing server name.
- 25524 SQL_LOGERR Server login error.
- 25525 BADTYPE Invalid data or record type.
- 25526 FIELDNAME Invalid field name.
- 25527 CLOSERR Error closing target file.
- 25528 DELETED Attempting to delete a record that is already marked as deleted.
- 25529 RECCRYPTERR Records are encrypted.
- 25530 RNOTOOBIG The record number is greater than maximum allowed.
- 25531 USERID Invalid user ID encountered.
- 25532 BADOPTIONNAME Invalid property name encountered.
- 25533 BADOPTIONVALUE Invalid property value encountered.
- 25534 INVALID Generic error meaning the connector encountered some type of unusual error condition.
- 25535 NOBROWSER Bad or missing data structure browser.
- 25536 NOMEMOFILE Bad or missing memo file. Some data formats use a separate file to store memo fields. Error is returned if the data source layout includes memo fields, but the memo file cannot be found.
- 25537 SORTFILE The target connector was unable to create a sort index file.
- 25538 SORTDUP Returned when a duplicate is encountered and duplicates are not allowed.
- 25539 FIELDCOUNT Too many fields in structure.
- 25540 MEMOCOUNT Too many memo fields in structure.
- 25541 MEMOPOS Memo field in wrong position in structure.
- 25542 TRUNCATE Returned by source and target connectors. For a target, this is returned only when the Truncation Handling option is set to error. For a source, it is returned when the Truncation Handling option is either warn or error. To change the settings, see "Setting General Logging Preferences" in the Intermediate and Advanced Mapping User’s Guide.
- 25543 RUNTIMERR Run-time error evaluating expressions.
- 25544 NOTSUP Indicates that a connector does not support a particular method.
- 25545 NOTIMP Indicates that a connector has not implemented a particular method.
- 25546 LICENSING Indicates that a particular connector or browser is not licensed for the product version.
- 25547 LOADLIBRARY Indicates that the load library for a particular connector or browser failed to load or could not be found.
- 25548 SUPPDLL Indicates that a load library required by the connector or browser (supporting load library) failed to load or could not be found.
- 25549 NEWPROC Indicates an error was encountered trying to get the address of a function in a load library.
- 25550 UNSPECIFIED An error occurred while loading a new connector or browser.
- 25551 USERABORT The loading of a connector or browser was aborted at the request of the user.
- 25552 OVERFLOW Returned by sources and targets. For a target, this is returned when the Overflow Handling option is set to error. For a source, it is returned when the Overflow Handling option is set to warn or error.
- 25553 NOCONNECTION No connection established.
- 25554 SQLEXECERR SQL statement execution error.
- 25555 EXTEXECERR External application execution error encountered.
- 25556 NULLINSERT Null value not allowed.
- 25557 NOTUNIQUE Key value not unique.
- 25558 CONSTRAINT Integrity constraint error encountered.
- 25559 DICTNOSOURCE Metadata source not defined.
- 25560 DICTOPENERR Error opening metadata source.
- 25561 DICTREADERR Error reading metadata.
- 25562 IOWAIT Waiting on input.
- 25563 MISMATCH No matching records for update.
- 25564 SQLTRANSACTION DEADLOCK Transaction deadlock detected.
- 25565 LICENSE_EXPIRED Appears only in code that is commented out.
- 25566 TIME_EXPIRED Indicates when a message expiration date is reached.
- 25567 ASSERTION_FAILED Indicates an Assert action failed.
- 25568 RECORD_INVALID Returned when a Validate Record action fails.
First, a connector (spoke) type was not selected for the source or target. In this case, error includes the message "Spoke type invalid or unspecified."
Second, it can mean that the requested connector cannot be loaded. In this case, the message "Unable to create new Connector" is used.
Reasons a connector cannot be loaded:
* The connector registry (connlist) cannot be found. The registry is usually located in the DataTools install directory. Invalid connector name given.
* DataTools is unable to locate the dynamic libraries required for the connector using the application search path.
* The -Initialization_Info command line option can be used to specify the name and location of the registry with the ConnListFile and LibraryPath entries.
* Problem with installation and configuration of third party dynamic libraries.
* Not enough system memory or other necessary resource.


Your transaction secured by high-grade AES-256 encryption.
Regarding error no 25542
We are using Ms Access (VBA) as front end to use Pervasive Data junction 7.5. Seems like one of my friend getting Error no 25542 while exporting file from SQL Server 2005 to text file. But for us same thing working fine. we do not know what is problem and where. Please advise.... Thanks,,
RE: Regarding error no 25542
As shown on this page of error codes, an error 25542 indicates that the data in one or more of the source fields is longer than the size of one or more of the target fields. Therefore, some of the data will be truncated in the target file unless the size of the affected target data field(s) is increased sufficiently to hold the source data.
Regarding error no 25542
Yes you are correct. Even though, we have same sizes in both Source and Target still geting Data Truncation. I checked in Database (Source) but i do not find any problems. One more thing. this is working us except one friend.
RE: Regarding error no 25542
Have you checked for non-printable characters in the source data?
Have you tried changing the Preference settings for truncation handling and/or error handling?
RE: Regarding error no 25542
Yes. We have checked this also. We do have NULL from this list. But, I believe this is not a problem. And, Truncation Handling set as Error for this mappings. This truncation problems(255542) happenings only running djmaps from my friend system though MS Access (VBA). But, its working fine for us. Is this system specific problem ?. We do not know what's the problem and where it is. Please advicse. Thanks...